Chemometrics I: spectra as data

Further reading — Chemometrics I: spectra as data

Quantitative biology and integrative omics

About this lecture

A spectrum is a curve: how much light a sample absorbs at each wavelength. Today we treat that curve as what it really is — a vector of numbers — and everything from the linear-algebra block suddenly applies to real chemistry.

  • What a spectrum is, and why “intensity vs wavelength” is just a high-dimensional vector.
  • The Beer–Lambert law: absorbance is proportional to concentration — the reason linear models are the natural language of spectroscopy.
  • Why raw spectra are messy, and the standard preprocessing toolkit: baseline correction, smoothing, normalization, derivatives.
  • Multivariate calibration: predicting a concentration from a whole spectrum, and why ordinary regression breaks — leading to PLS.

This is an Applications unit: it reuses dot products, linear models, and principal component analysis on data biologists and chemists actually collect.

Light spectra can measure glucose without sampling

You have a bioreactor of cells and you want to know the glucose concentration in the medium — continuously, without pipetting out samples and running an assay every hour.

  • Shine near-infrared (NIR) light through the medium and record how much is absorbed at each wavelength.
  • Glucose, lactate, protein, water each absorb light in their own characteristic pattern.
  • The measured spectrum is a mixture of all of these, weighted by how much of each is present.

The task: read the concentration off the spectrum. Cheap, fast, non-destructive, and it works on living cultures, food, tissue, blood, soil.

A spectrum is the absorbance at each wavelength

Pass light of many wavelengths through a sample and, for each wavelength \lambda, measure how much is absorbed.

  • Transmittance T = I / I_0: fraction of light that gets through.
  • Absorbance A = -\log_{10}(T) = \log_{10}(I_0 / I): the quantity chemists model, because it behaves linearly (next slides).

A spectrum is the function A(\lambda) — absorbance at each wavelength.

Technique Probes Typical use
UV–Vis electronic transitions DNA/protein quantification
IR / NIR molecular vibrations composition, moisture, sugars
Raman vibrational (scattering) aqueous samples, live cells

A spectrum is a vector

The instrument does not record a smooth curve — it records absorbance at a discrete grid of wavelengths \lambda_1, \lambda_2, \dots, \lambda_p.

\mathbf{x} = (A(\lambda_1),\ A(\lambda_2),\ \dots,\ A(\lambda_p)) \qquad (p \text{ numbers})

  • Each wavelength is a coordinate; a spectrum is one point in a p-dimensional space.
  • p is large — often several hundred to a few thousand wavelengths.
  • Two similar samples give two nearby points; the distance between spectra is an ordinary vector distance.

Everything from Vectors and dot products applies: length, distance, angle, projection — now on chemical data.

Spectra stack into a samples-by-wavelengths matrix

Measure n samples, each on the same grid of p wavelengths. Stack the spectra as rows:

X = \begin{pmatrix} \text{— spectrum}_1 \text{ —} \\ \text{— spectrum}_2 \text{ —} \\ \vdots \\ \text{— spectrum}_n \text{ —} \end{pmatrix} \quad (n \times p)

  • Rows = samples, columns = wavelengths. Same layout as an expression matrix (samples × features).
  • Usually wide: far more wavelengths than samples, p \gg n.
# X: 50 samples (rows) measured at 700 wavelengths (columns)
dim(X)              # 50 700
X[1, ]              # the first spectrum, as a length-700 vector
matplot(t(X), type = "l")   # overlay all spectra: wavelength on x, absorbance on y

Absorbance is proportional to concentration

For a single absorbing substance, absorbance is proportional to concentration:

A = \varepsilon\, \ell\, c

  • c — concentration of the substance,
  • \ell — path length the light travels through the sample,
  • \varepsilon — molar absorptivity, a constant of the substance at that wavelength.

Double the concentration → double the absorbance. This is the linear relationship at the heart of quantitative spectroscopy.

At a fixed path length, at one wavelength, A is just a straight line through the origin in c: A = (\varepsilon\ell)\,c.

A mixture spectrum is a weighted sum of pure spectra

Real samples contain many absorbing species. At each wavelength, their absorbances simply add:

A(\lambda) = \varepsilon_1(\lambda)\,\ell\,c_1 + \varepsilon_2(\lambda)\,\ell\,c_2 + \dots + \varepsilon_k(\lambda)\,\ell\,c_k

Writing the whole spectrum at once, with \mathbf{s}_i the pure-component spectrum of substance i:

\mathbf{x} = c_1\mathbf{s}_1 + c_2\mathbf{s}_2 + \dots + c_k\mathbf{s}_k

A measured spectrum is a linear combination of pure-component spectra, weighted by concentrations.

  • This is exactly a linear model — the same object as in Linear models, now with spectra as the vectors.
  • Recovering the c_i from \mathbf{x} is the calibration problem.

Raw spectra carry artefacts unrelated to chemistry

Beer–Lambert is clean; real instruments and samples are not. Raw spectra carry artefacts unrelated to chemistry:

  • Baseline drift / offset — the whole curve floats up or down (light scattering, instrument warm-up).
  • Multiplicative scaling — path length and particle size scale the whole spectrum up or down.
  • Random noise — detector noise wiggles on top of the signal.
  • Overlapping peaks — chemically distinct bands blur into one broad hump.

If we feed these straight into a model, it will happily fit the artefacts instead of the chemistry.

Preprocessing 1 — baseline correction

An additive baseline shifts the whole spectrum: A_\text{measured}(\lambda) = A_\text{true}(\lambda) + b(\lambda).

  • Simplest case: a constant offset b — subtract the minimum, or the value at a signal-free wavelength.
  • General case: a slowly varying curved baseline — fit a smooth curve (polynomial, asymmetric least squares) and subtract it.
# constant-offset removal: subtract each spectrum's own minimum
X_bc <- X - apply(X, 1, min)      # per-row (per-sample) baseline

# a signal-free anchor wavelength (say column 1) set to zero
X_bc <- X - X[, 1]

Goal: two samples with the same chemistry but different baselines should end up on top of each other.

Preprocessing 2 — smoothing

High-frequency noise rides on top of the real, smooth bands. Averaging neighbouring wavelengths suppresses it.

  • Moving average: replace each point with the mean of a small window — simple, but blunts peaks.
  • Savitzky–Golay: fit a low-order polynomial in a sliding window and take its value at the centre — smooths while preserving peak shape. The standard choice.
# crude moving-average smoother (window of 5), illustrative only
smooth5 <- function(v) stats::filter(v, rep(1/5, 5))
X_sm <- t(apply(X, 1, smooth5))

Trade-off: too little smoothing leaves noise; too much erases real narrow peaks. Choose the window deliberately.

Preprocessing 3 — normalization

Multiplicative effects (path length, particle size, sample density) scale the whole spectrum by an unknown factor. Normalization removes that scale.

  • Vector normalization: divide each spectrum by its own length \lVert\mathbf{x}\rVert → all spectra have length 1.
  • Standard Normal Variate (SNV): per spectrum, subtract its mean and divide by its standard deviation (centre + scale each row).
# vector (L2) normalization: each spectrum scaled to unit length
X_vn <- X / sqrt(rowSums(X^2))

# SNV: centre and scale each spectrum (row) on its own statistics
X_snv <- t(scale(t(X)))     # scale() works on columns, so transpose in/out

Now differences between spectra reflect shape (composition), not overall intensity.

Preprocessing 4 — derivatives

Taking the derivative of the spectrum with respect to wavelength is a preprocessing step in its own right.

  • First derivative removes a constant baseline offset (the derivative of a constant is zero).
  • Second derivative removes a linear (sloping) baseline, and sharpens overlapping peaks into resolvable dips.

In practice the derivative is computed and smoothed together, usually by Savitzky–Golay (fit a polynomial, differentiate it).

# crude first difference along wavelength: approximates the derivative
X_d1 <- t(apply(X, 1, diff))      # one column shorter than X

Cost: differentiation amplifies noise, which is why it is paired with smoothing.

Calibration predicts concentration from a spectrum

We have n calibration samples with spectra (matrix X, n \times p) and known reference concentrations (vector \mathbf{y}, measured by a slow gold-standard assay).

Goal: learn a rule that turns a new spectrum into a predicted concentration — so future samples skip the slow assay.

A linear predictor (the natural choice, from Beer–Lambert) is a weighted sum of the absorbances:

\hat{y} = b_0 + b_1 x_1 + b_2 x_2 + \dots + b_p x_p = b_0 + \mathbf{b}\cdot\mathbf{x}

  • The weights \mathbf{b} = (b_1,\dots,b_p) are a vector, one weight per wavelength.
  • Predicting is a single dot product between the coefficient vector and the spectrum.

Many correlated wavelengths break ordinary least squares

Ordinary least squares needs to invert X^\top X (a p\times p matrix). On spectra it fails on two counts:

  • p \gg n: with more wavelengths than samples, X^\top X is singular — no unique solution. Infinitely many coefficient vectors fit the calibration data perfectly and predict garbage on new samples (overfitting).
  • Collinearity: adjacent wavelengths are almost identical (spectra are smooth), so columns of X are highly correlated — even when n > p, X^\top X is near-singular and the coefficients are wildly unstable.

We need a method that works when predictors are many and correlated. The idea: compress the spectrum into a few good directions first.

PLS picks components that track concentration

Reduce the p correlated wavelengths to a few latent variables — weighted combinations of wavelengths — then regress on those.

  • Principal Component Regression (PCR): run principal component analysis on X (from the PCA unit), keep the top few components, regress \mathbf{y} on their scores. Components are chosen to capture variance in X — but the biggest variance might be nuisance, not analyte.
  • Partial Least Squares (PLS): choose components that capture variance in X and correlate with \mathbf{y}. It uses the response while building the components.

PLS is the workhorse of chemometric calibration because it aims its components at the quantity you want to predict.

PLS builds components one at a time

PLS builds a small number of latent variables (components), one at a time:

  1. Find the direction in wavelength space \mathbf{w}_1 along which the spectra vary and that variation tracks \mathbf{y} (maximal covariance with \mathbf{y}).
  2. Project every spectrum onto it → a score t_1 (one number per sample).
  3. Use t_1 to predict \mathbf{y}; remove what it explained from both X and \mathbf{y}.
  4. Repeat on the remainder for \mathbf{w}_2, \mathbf{w}_3, \dots
  • Each component is a linear combination of wavelengths — a direction (a vector) in spectral space.
  • The number of components is the one dial to tune — chosen by cross-validation.

PLS in R

The pls package fits PLS with built-in cross-validation. Illustrative workflow (not run here):

library(pls)

# df has a response column `conc` and a spectral matrix column `X`
fit <- plsr(conc ~ X, data = df, ncomp = 10, validation = "CV")

# how many components? look for where CV error stops improving
validationplot(fit, val.type = "RMSEP")

# predict a new spectrum using, say, 4 components
predict(fit, newdata = new_df, ncomp = 4)
  • validation = "CV" cross-validates over component counts.
  • RMSEP (root-mean-square error of prediction) tells you the expected error on new samples — pick the smallest sensible ncomp.

Every step here reuses a linear-algebra idea

Chemometrics idea Course concept
Spectrum = intensity vs wavelength a vector of p numbers
Distance / similarity of spectra norm, dot product, angle
Mixture spectrum linear combination of pure spectra
Predict concentration linear model, \hat y = b_0 + \mathbf{b}\cdot\mathbf{x}
Compress correlated wavelengths principal component analysis
Supervised compression PLS (PCA’s response-aware cousin)

Beer–Lambert makes the chemistry linear; the linear-algebra block is precisely the toolkit for linear things.

Summary

  • A spectrum is a high-dimensional vector: absorbance at each wavelength. A dataset is a wide matrix, samples × wavelengths, usually p \gg n.
  • Beer–Lambert (A = \varepsilon\ell c) makes absorbance proportional to concentration, and mixture spectra are linear combinations of pure-component spectra — so linear models are the natural fit.
  • Raw spectra need preprocessing: baseline correction (additive), normalization (multiplicative), smoothing (noise), derivatives (baseline + overlap). These are validated, not guessed.
  • Multivariate calibration predicts concentration from a spectrum. Ordinary regression fails (p\gg n, collinearity); PLS compresses wavelengths into a few response-aware components, tuned by cross-validation.

Next (Chemometrics II): classification of spectra, model validation, and interpreting which wavelengths drive a prediction.