Further reading: not part of the course.
This material is not included in the course, but it is relevant if you want to learn more about the topic.
Chemometrics II: applications
Further reading — Chemometrics II: applications
Quantitative biology and integrative omics
Draft skeleton — review before use
This unit is a DRAFT SKELETON
This lecture is a provisional outline written to hold the slot for Chemometrics II while a subject-matter contributor is recruited. It sketches the standard applications at a general level only.
Treat every claim as provisional and subject to expert review.
No specific instrument, dataset, threshold, or performance number here is authoritative — where a concrete value would normally appear, the text says so rather than inventing one.
Do not teach from this unit as-is. It must be reviewed, corrected, and fleshed out by someone with hands-on chemometrics experience before it is used in class.
Reviewer checklist appears in the speaker notes throughout, tagged [REVIEW].
About this lecture
Chemometrics I introduced the setting: a spectrum is a high-dimensional vector, samples stack into a wide matrix, and PCA-style methods find structure in it. Today we turn to what we do with such data in practice.
By the end you should be able to:
frame a spectroscopy problem as either classification (which group?) or regression / calibration (how much?),
describe multivariate calibration and why spectra need it rather than plain lm,
explain what calibration transfer is and why a model can fail on a second instrument,
recognise multivariate process / quality control on scores and residuals,
state why variable selection helps and name a couple of standard approaches,
validate a model honestly with cross-validation and report RMSEP.
This is an applications and vocabulary day, built on the machinery from PCA, The OPLS model, and Chemometrics I.
Spectra are fast, cheap stand-ins for lab assays
Spectroscopy gives a fast, cheap, often non-destructive read-out that stands in for a slow wet-lab assay. Some recurring biological uses:
Near-infrared (NIR) / infrared (IR): composition of grain, feed, tissue, or fermentation broth — e.g. protein, moisture, or metabolite content without a full chemical assay.
Raman: label-free readout of cells and tissue; distinguishing cell states or identifying microbial isolates.
Mass spectrometry / NMR (metabolomics): hundreds to thousands of features per sample, used to separate phenotypes or detect a metabolic shift.
In every case the raw signal is many correlated numbers per sample, and the biological answer — a concentration or a class label — is hidden in their pattern, not any single channel.
Wide, correlated spectra break ordinary least squares
Stack n samples, each measured at p wavelengths, into a matrix X (n \times p), with a target \mathbf{y} (a property to predict, or a class):
Wide: often p \gg n (far more wavelengths than samples).
Collinear: neighbouring wavelengths are highly correlated — they carry nearly the same information.
Ordinary least squares (lm) breaks here: with p \gg n and collinear columns, X^\top X is not invertible and the fit is unstable. This is exactly the problem the latent-variable methods from PCA and The OPLS model were built to solve.
Fix preprocessing on the training data only
Raw spectra carry nuisance variation — scatter, baseline drift, path-length differences — that has nothing to do with the biology. Standard preprocessing steps (named here for recognition; details belong to Chemometrics I / an expert pass):
Baseline / scatter correction: e.g. Standard Normal Variate (SNV), Multiplicative Scatter Correction (MSC).
Centering / scaling: mean-centre columns; sometimes autoscale (unit variance) so no channel dominates by magnitude alone.
Important
Preprocessing choices are part of the model. They must be decided on the training data and re-applied identically to new data — never fit using information from the test set.
Spectra answer either “how much?” or “which group?”
Almost every spectral application is one of two supervised tasks:
Question
Target \mathbf{y}
“How much / which?”
Typical methods
Regression (calibration)
continuous
How much analyte?
PCR, PLS regression
Classification
categorical
Which group / is it OK?
PLS-DA, LDA, SIMCA, k-NN
Both share the same trick learned earlier: project the wide, collinear X onto a few latent components first, then model in that low-dimensional space.
Regression fits a line/plane in latent space (property vs components).
Classification separates groups in latent space.
We take them in turn.
PLS calibration aims its components at the target
Goal: predict a continuous property y (e.g. concentration) from a spectrum \mathbf{x}.
The physical motivation is roughly linear: by the Beer–Lambert idea, absorbance rises with concentration, so a linear model in the (preprocessed) spectrum is a sensible starting point:
\hat{y} = b_0 + \mathbf{x}^\top \mathbf{b}
But we cannot fit \mathbf{b} directly by ordinary least squares (p \gg n, collinear). Instead:
PCR (Principal Component Regression): run PCA on X, keep the top components, regress y on the scores.
PLS regression: like PCR, but the components are chosen to align with y — they explain variation in Xthat is relevant to y, not just the largest variation in X.
PLS is the standard chemometrics calibration tool for exactly this reason.
Calibration in R (sketch)
Static illustration only — no packages are installed at render time, so nothing here is executed. The pls package provides plsr().
library(pls)# X: n x p spectra (preprocessed), y: property to predict, in one data framefit <-plsr(y ~ ., data = train,ncomp =10, # try up to 10 latent componentsvalidation ="CV") # built-in cross-validation# how many components? read the cross-validated error, pick the elbowvalidationplot(fit, val.type ="RMSEP")summary(fit)# predict a held-out set with the chosen number of componentsyhat <-predict(fit, newdata = test, ncomp =4)
The single most important decision is how many components to keep — too few underfits, too many overfits. That decision is made by validation, which is the rest of this lecture.
Too few components underfit; too many fit noise
Every latent-variable model has a complexity dial: the number of components (latent variables) kept.
Too few components: the model misses real signal — underfitting (high error everywhere).
Too many components: the model starts fitting noise in the training spectra — overfitting (training error keeps dropping, but error on new samples rises).
The training-set error alone cannot tell you where to stop — it always improves with more components. You need an estimate of error on unseen data. That is what cross-validation provides.
Only untouched test samples show real performance
A model that has seen a sample can predict it well — that proves nothing about future samples.
Calibration (training) error, RMSEC: error on the samples used to fit. Optimistic — always looks better than reality.
Prediction error, RMSEP: error on an independent set the model never touched during fitting or tuning. This is the number you report and trust.
Important
Anything fit on the data — preprocessing, scaling, component count, variable selection — must be decided without the test set. Otherwise the test set is contaminated and RMSEP is optimistic.
The honest workflow: train to fit, validate to tune, test once to report.
Each sample is predicted by a model that never saw it
When data are scarce, holding out one fixed test set wastes samples. k-fold cross-validation reuses them:
Split the samples into k roughly equal folds.
For each fold: train on the other k-1 folds, predict the held-out fold.
Every sample is predicted exactly once, by a model that did not see it.
Combine the held-out predictions into one error estimate.
Leave-one-out (LOO):k = n (each sample its own fold) — common for small spectral sets.
In spectroscopy, samples measured together can be correlated; folds should respect that (e.g. do not split replicate scans of the same specimen across folds).
RMSEP gives prediction error in the target’s units
The standard regression error is the root-mean-square error of prediction:
Same units as y (e.g. mg/mL) — directly interpretable.
Computed on an independent set → RMSEP; from cross-validation → RMSECV; on the training set → RMSEC (optimistic).
Report alongside it:
Bias: mean of (\hat{y}_i - y_i) — a systematic offset (ideally \approx 0).
R^2 / explained variance: fraction of variation in y captured.
Pick the component count that minimises RMSECV (or the simplest model within noise of the minimum — the “one-standard-error” idea).
Classification uses the same components and validation
Goal: assign each spectrum to a class — tissue type, disease vs control, species of a microbial isolate, pass/fail.
Same latent-projection idea, now separating groups:
PLS-DA: encode the class as a numeric target and run PLS regression toward it; assign by the predicted value. The default chemometrics classifier.
LDA: find the direction that best separates classes (often applied after PCA to tame p \gg n).
SIMCA: build a separate PCA model per class; a new sample joins the class whose model it fits best (can also say “none of them”).
k-NN: classify by the nearest training spectra in (latent) space.
Validate with the same discipline: cross-validated misclassification rate, sensitivity/specificity, or a confusion matrix on an independent test set — never the training accuracy.
A model may need adjusting for a new instrument
A model calibrated on instrument A often fails on instrument B — different detector, different day, different temperature — because the same sample produces a slightly different spectrum.
Calibration transfer adapts a model so it works across instruments/conditions without rebuilding it from scratch:
Measure a small set of transfer / standardisation samples on both instruments.
Learn a mapping that makes B’s spectra look like A’s (or adjust the model coefficients).
Standard families (named for recognition): Direct Standardization (DS) and Piecewise Direct Standardization (PDS), and other spectral-space corrections.
For a biologist this is the difference between a model that lives only in the lab that built it and one that transfers to a collaborator, a clinic, or next year’s instrument.
Two distance scores flag unusual samples
Once a good latent-variable model exists, use it to monitor a process or screen samples in real time — multivariate statistical process control (MSPC).
Two complementary alarms per new sample:
Hotelling’s T^2: how far the sample sits from the centre inside the model’s latent space — unusual but of a known type of variation.
Q / SPE (squared prediction error): how far the sample lies off the model subspace — variation the model has never seen (a new, possibly out-of-spec state).
Plot these on control charts with limits; a point past a limit flags a sample or batch for attention.
Select wavelengths inside cross-validation
Spectra have hundreds of channels, but often only some carry the relevant signal. Selecting variables (wavelengths) can:
improve interpretability — which spectral regions drive the prediction (a chemically/biologically meaningful band),
sometimes improve robustness by dropping noisy, uninformative channels,
but risks overfitting the selection itself if not validated properly.
Standard approaches, named for recognition:
VIP (Variable Importance in Projection) scores from a PLS model,
selectivity ratio, interval methods (iPLS), or search-based selection.
Important
Variable selection is part of model fitting. Select inside the cross-validation loop, not before it — otherwise the reported error is optimistic.
Good practice checklist
Independent of the specific method, a trustworthy spectral model:
preprocesses consistently, with all choices fixed on training data only;
keeps a truly independent test set, touched once, at the end;